Flame Retardant Rubber Sheet Fire Resistant | Industrial Grade | Sold Per Metre | RubberMatting-Direct

SKU: RMD-RS-FR-03-1200

£95.00/metreInc. VAT£112.10SAVE 15%
Sold by the linear metre — Select quantity below for your required length
Example: 5 metres = £475.00

Pay in 3 interest-free instalments of £31.66 with Shop Pay

In Stock - Ready to Ship
FREE UK Delivery — Same day dispatch Mon–Fri if ordered by 2pm
Length (metres):
Your Total: £95.00
Free UK Delivery
Same Day Dispatch
14 Day Returns
Secure Checkout

Flame Retardant Rubber Sheet – Fire Resistant Industrial Grade

Our flame retardant rubber sheet meets stringent fire safety standards, making it essential for applications where fire risk must be minimised. This self-extinguishing FR rubber won't propagate flames and is designed for use in high-risk environments including underground mining, railway, marine, and public building applications.

Manufactured from a fire-resistant Neoprene/EPDM blend, this industrial-grade rubber sheet complies with relevant fire safety regulations and provides peace of mind in safety-critical installations. When exposed to flame, the material self-extinguishes rather than continuing to burn.

Flame Retardant Specifications

Property Value
Material FR Neoprene/EPDM Blend
Fire Rating Self-Extinguishing (SE)
Thickness Options 3mm, 5mm, 6mm
Width 1200mm (1.2m)
Sold By Linear Metre
Temperature Range -30°C to +90°C
Shore Hardness 65 ±5 Shore A
Surface Finish Smooth both sides
Colour Black
Compliance BS 476, EN 45545-2 (on request)

Why Choose Flame Retardant Rubber?

  • Self-extinguishing – stops burning when ignition source is removed
  • Won't propagate flames – prevents fire spread
  • Low smoke emission – critical for enclosed spaces
  • Compliance ready – meets building regulations and industry standards
  • Dual function – fire resistance plus standard rubber properties
  • Insurance requirements – often mandatory in commercial/industrial settings

Fire Safety Applications

  • Underground mining – conveyor skirting, walkways, machine guarding
  • Railway rolling stock – floor coverings, vibration isolation
  • Public buildings – schools, hospitals, care homes, hotels
  • Marine vessels – deck coverings, engine room flooring
  • HVAC systems – duct lining, vibration isolation
  • Electrical installations – switchroom flooring, transformer bases
  • Data centres – raised floor systems, cable management
  • Theatres and cinemas – stage flooring, acoustic treatment

Related Products

Explore our specialist rubber sheeting range:

Frequently Asked Questions

What fire rating does this rubber sheet have?

This flame retardant rubber is self-extinguishing, meaning it will stop burning once the ignition source is removed. It meets BS 476 requirements for surface spread of flame. For specific certifications (EN 45545-2 for railway, marine approvals), please contact us with your requirements and we can provide appropriate documentation.

Is this rubber suitable for underground mining applications?

Yes, this FR rubber sheet is specifically designed for underground mining environments where fire risk is critical. It's suitable for conveyor skirting, walkways, and machine guarding. The self-extinguishing properties and low smoke emission make it compliant with mine safety regulations.

What's the difference between flame retardant and standard rubber?

Standard SBR rubber will burn when exposed to flame. Flame retardant rubber contains fire-inhibiting additives that make it self-extinguishing – it stops burning when the flame source is removed. FR rubber also produces less smoke and toxic fumes. The trade-off is slightly higher cost, but this is essential for safety-critical applications.

Can I get fire certification documentation for building control?

Yes, we can provide test certificates and material data sheets for building control approval. Please contact us before ordering if you need specific documentation. We can also supply samples for independent testing if required for your project.

What thickness should I choose for floor covering?

For floor coverings in public buildings, 3mm is usually sufficient. For industrial applications with heavy foot traffic or trolleys, choose 5mm. For areas with vehicle traffic or where additional impact protection is needed (e.g., mining equipment), 6mm provides maximum durability.

Why Choose RubberMatting-Direct?

  • FREE UK Delivery on all orders
  • Cut to your length – order exactly what you need
  • Fire certificates available – for building control
  • Trade prices – direct from importer
  • Expert advice – call us for specifications

Download Spec Sheet

PDF with image, specifications & dimensions

Product Specifications

  • Commercial-grade rubber construction
  • Heavy-duty industrial grade
  • Cut to your required size
  • Free UK delivery on qualifying orders
We accept:
Visa Generic Generic Apple Pay Google Pay PayPal

Trusted by Leading Companies

10,000+ Happy Customers
15+ Years Experience
4.9★ Average Rating

Description

Flame Retardant Rubber Sheet – Fire Resistant Industrial Grade

Our flame retardant rubber sheet meets stringent fire safety standards, making it essential for applications where fire risk must be minimised. This self-extinguishing FR rubber won't propagate flames and is designed for use in high-risk environments including underground mining, railway, marine, and public building applications.

Manufactured from a fire-resistant Neoprene/EPDM blend, this industrial-grade rubber sheet complies with relevant fire safety regulations and provides peace of mind in safety-critical installations. When exposed to flame, the material self-extinguishes rather than continuing to burn.

Flame Retardant Specifications

Property Value
Material FR Neoprene/EPDM Blend
Fire Rating Self-Extinguishing (SE)
Thickness Options 3mm, 5mm, 6mm
Width 1200mm (1.2m)
Sold By Linear Metre
Temperature Range -30°C to +90°C
Shore Hardness 65 ±5 Shore A
Surface Finish Smooth both sides
Colour Black
Compliance BS 476, EN 45545-2 (on request)

Why Choose Flame Retardant Rubber?

  • Self-extinguishing – stops burning when ignition source is removed
  • Won't propagate flames – prevents fire spread
  • Low smoke emission – critical for enclosed spaces
  • Compliance ready – meets building regulations and industry standards
  • Dual function – fire resistance plus standard rubber properties
  • Insurance requirements – often mandatory in commercial/industrial settings

Fire Safety Applications

  • Underground mining – conveyor skirting, walkways, machine guarding
  • Railway rolling stock – floor coverings, vibration isolation
  • Public buildings – schools, hospitals, care homes, hotels
  • Marine vessels – deck coverings, engine room flooring
  • HVAC systems – duct lining, vibration isolation
  • Electrical installations – switchroom flooring, transformer bases
  • Data centres – raised floor systems, cable management
  • Theatres and cinemas – stage flooring, acoustic treatment

Related Products

Explore our specialist rubber sheeting range:

Frequently Asked Questions

What fire rating does this rubber sheet have?

This flame retardant rubber is self-extinguishing, meaning it will stop burning once the ignition source is removed. It meets BS 476 requirements for surface spread of flame. For specific certifications (EN 45545-2 for railway, marine approvals), please contact us with your requirements and we can provide appropriate documentation.

Is this rubber suitable for underground mining applications?

Yes, this FR rubber sheet is specifically designed for underground mining environments where fire risk is critical. It's suitable for conveyor skirting, walkways, and machine guarding. The self-extinguishing properties and low smoke emission make it compliant with mine safety regulations.

What's the difference between flame retardant and standard rubber?

Standard SBR rubber will burn when exposed to flame. Flame retardant rubber contains fire-inhibiting additives that make it self-extinguishing – it stops burning when the flame source is removed. FR rubber also produces less smoke and toxic fumes. The trade-off is slightly higher cost, but this is essential for safety-critical applications.

Can I get fire certification documentation for building control?

Yes, we can provide test certificates and material data sheets for building control approval. Please contact us before ordering if you need specific documentation. We can also supply samples for independent testing if required for your project.

What thickness should I choose for floor covering?

For floor coverings in public buildings, 3mm is usually sufficient. For industrial applications with heavy foot traffic or trolleys, choose 5mm. For areas with vehicle traffic or where additional impact protection is needed (e.g., mining equipment), 6mm provides maximum durability.

Why Choose RubberMatting-Direct?

  • FREE UK Delivery on all orders
  • Cut to your length – order exactly what you need
  • Fire certificates available – for building control
  • Trade prices – direct from importer
  • Expert advice – call us for specifications
Flame Retardant Rubber Sheet Fire Resistant | Industrial Grade | Sold Per Metre | RubberMatting-Direct

Flame Retardant Rubber Sheet Fire Resistant | Industrial Grade | Sold Per Metre | RubberMatting-Direct

£95.00 £112.10
Free Delivery UK Stock
✨ Perfect Pairings

Frequently Bought Together

Customers who viewed this also viewed these products

Recently viewed