Description
EPDM Wall Flashing Trim | Weatherproof Wall Abutment Solution
Create a professional, watertight seal where your flat roof meets a wall with this powder-coated aluminium wall flashing trim. Essential for extension roofs, lean-to structures, and any EPDM installation that abuts an existing building, this trim ensures water cannot penetrate at the critical wall junction.
π§ Specifications
| Length | 2.5 metres per piece |
|---|---|
| Material | Extruded aluminium, powder-coated finish |
| Profile Type | Wall abutment / flashing |
| Wall Upstand | Approximately 75mm |
| Roof Overlap | Approximately 50mm |
| Colours | Black, Anthracite Grey |
| Fixing Method | Mechanical fixings + sealant |
| Compatibility | All EPDM membranes 1.2mm-1.5mm |
β Key Benefits
- Weatherproof Seal β Prevents water ingress at wall abutments
- Professional Finish β Clean, defined junction between roof and wall
- Durable Construction β Aluminium won't rust, rot, or degrade
- Easy Installation β Mechanical fix with sealant backing
- Colour Matched β Coordinates with EPDM and modern exterior finishes
- Low Maintenance β No repainting or retreating required
- Building Regs Compliant β Meets requirements for flat roof abutments
π Perfect For
- Extension roofs joining the main house
- Garage roofs against house walls
- Garden rooms and home offices
- Lean-to structures and porches
- Kitchen extensions with flat roofs
- Commercial buildings with parapet walls
- Any roof-to-wall junction requiring weatherproofing
π Why Wall Flashing Matters
The junction between a flat roof and a wall is one of the most vulnerable points for water ingress. Without proper flashing:
- Rain runs down the wall and behind the membrane
- Wind-driven rain forces water into small gaps
- Thermal movement creates openings over time
- Damp penetrates into the building structure
This aluminium wall flashing provides a permanent, mechanical barrier that works with the EPDM membrane to create a fully sealed junction.
π οΈ Installation Guide
- Prepare the Wall β Clean masonry, remove loose material, ensure surface is dry
- Mark Position β Draw a level line 75-100mm above the roof surface
- Apply Sealant Backing β Run a continuous bead of silicone along the fixing line
- Position Flashing β Press into sealant with wall upstand against the wall
- Mechanical Fix β Drill and plug at 300mm centres, secure with screws
- Seal Top Edge β Apply another bead of sealant along the top of the flashing
- Bond EPDM Membrane β Bring membrane up and over the roof overlap section
- Roll & Seal β Use seam roller to ensure full adhesive contact
π Critical Installation Tips
- Height matters β Position flashing minimum 75mm above roof level to prevent splashback issues
- Chase into brick? β For traditional lead-style finish, flashing can be chased into a mortar course
- Corner joints β Use pre-formed corner pieces or carefully mitre-cut and seal corners
- Multiple walls β Calculate all wall lengths and add 10% for overlaps
π¦ Calculating Quantities
Each piece covers 2.5 metres of wall length. To calculate:
- Measure total wall abutment length in metres
- Divide by 2.5
- Add 10% for overlaps and wastage
- Round up to whole number
Example: 6m wall length Γ· 2.5 = 2.4, +10% = 2.6 β Order 3 pieces
π Complete Your EPDM System
For a watertight installation, combine with:
- EPDM Membrane β Main roofing surface
- EPDM Corner Pieces β Internal and external corners
- EPDM Drip Edge β Roof edges over guttering
- EPDM Kerb Edge β Raised perimeter edges
- EPDM Contact Adhesive β For all bonding
- Silicone Sealant β For top edge sealing (use roof-grade silicone)
π Technical Properties
| Property | Value |
|---|---|
| Aluminium Grade | 6063-T5 (architectural grade) |
| Powder Coating | Polyester, 60-80 microns |
| Corrosion Resistance | Excellent (coastal suitable) |
| Temperature Range | -40Β°C to +80Β°C |
| UV Stability | Excellent (no fading) |
| Fire Rating | Non-combustible |
π¬ Frequently Asked Questions
Q: Do I need to chase this into the wall like traditional lead flashing?
A: Not necessarily. Surface-mounted installation with sealant provides excellent weatherproofing. However, for a more traditional appearance or in exposed locations, you can chase the top edge into a mortar joint.
Q: What sealant should I use?
A: Use a high-quality roof and gutter silicone sealant, compatible with aluminium. Apply generously behind the flashing and along the top edge.
Q: Can this be used on rendered walls?
A: Yes, but ensure the render is in good condition and firmly adhered. On new render, allow full curing time before installation.
Q: How do I handle internal corners?
A: For internal corners, mitre-cut two pieces at 45Β° and join with sealant. Alternatively, use pre-formed internal corner pieces for a neater finish.
Q: Is this suitable for parapet walls?
A: Yes, use on parapet walls in combination with kerb edge trims for a complete sealed perimeter.
β Free UK Delivery | π UK-Based Support | π 14-Day Returns
Professional EPDM wall flashing from Rubber Matting Direct β creating watertight abutments for lasting protection.
EPDM Wall Flashing Trim | 2.5m Length | Aluminium | Wall Abutment
Frequently Bought Together...
Trusted by Leading Organisations
Frequently Bought Together
Customers who viewed this also viewed these products






